Number of rounds 6
Voltage value 12 V
Ampere rating 100 Ah @ 20 Hr Rate to 1.75V Per Cell @ 25 ℃ (77 ℉)
Weight: 30.6 Kg (67.44 lbs)
Maximum discharge current 800A (5 Sec)
Internal resistance Approx. 4.4 m Ω
Temperature working range Discharge: -15 ℃~50 ℃ (5 ° F~122 ° F)
Charge: -15 ℃~40 ℃ (5 ° F~104 ° F)
Storage: -15 ℃~40 ℃ (5 ° F~104 ° F)
General operating temperature range: 25 ℃± 3 ℃ (77 ° F ± 5 ° F)
Float charging uses a charging voltage of 13.5 to 13.8 VDC/Unit Average at 25 ℃ (77 ° F)
Suggest a maximum charging current of 30A
Uniform charging uses charging voltage of 14.4 to 15.0 VDC/Unit Average at 25 ℃ (77 ° F)
It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temperature
Terminal I2 Thread lead alloy received terminal to accept M6 bolt
Cell material Polypropylene (UL 94-HB)&Flammability resistance
Of (UL 94-V0) can be available upon request
“
"GP series
GP 121000"
"Valve Regulated Lead Acid Battery
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%."
General Design for Standby Power Applications
"【Design Life】
Up to 5 Years in Standby Service at 25℃ Eurobat (20℃) : 3-5 years, Standard Commercial
【 Operating Temperature Range】
Nominal Operating Temperature : 25℃(77℉) Discharge : -15℃ ~ 50℃ (5℉~122℉) Charge: -15℃ ~ 40℃ (5℉~104℉)
Storage: -15℃ ~ 40℃ (5℉~104℉)" "【 Float Charging Voltage】
13.5 ~ 13.8 VDC/Unit at 25℃ (77℉)
【Equalization Charging Voltage 】
14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
【 Self Discharge】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉)."
Specification Design according with IEC 60896-21/22: 2004
"Nominal Voltage 12V (6 cells per unit)
Nominal Capacity 100 Ah @20hr-rate to 1.75V per cell @25℃ (77℉)
Weight Approx. 30.60 Kg (67.44 lbs) Maximum Discharge Current 800A (5sec)
Internal Resistance Approx. 4.4mΩ
Short Circuit Current 2323A
Maximum Charge Current 30.00A
Terminal types I2 terminal to accept M6 bolt
Terminal tightening torque 51.7±10.3 Kgf·cm / 44.9±9.0 Lbf·in / 5.10±1.0 N·m
Container Material PP (UL 94-HB) & Flame Retardant (94-V0) available upon request
Length (L) 343.0±2.5 mm 13.50±0.10 inch
Width (W) 170.0±2.0 mm 6.69±0.08 inch
Dimensions
Container Height (h) 213.9±2.5 mm 8.42±0.10 inch
Overall Height (H) 216.9±2.5 mm 8.54±0.10 inch"
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time 5 MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 372 257 197 121 70.1 50.4 39.9 29.0 18.6 12.3 10.1 5.26
1.67V 326 242 187 117 68.8 49.5 39.2 28.6 18.3 12.1 9.94 5.23
1.70V 315 234 183 116 68.1 49.1 38.9 28.4 18.2 12.0 9.86 5.20
1.75V 286 213 175 113 66.8 48.3 38.4 27.9 17.9 11.8 9.72 5.10
1.80V 241 192 157 105 65.4 47.3 37.6 27.3 17.5 11.5 9.59 5.00
1.85V 202 165 135 96.8 62.5 46.0 36.6 26.5 17.1 11.2 9.24 4.80
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 3593 2696 2223 1366 802 579 459 335 216 143 117 61.1
1.67V 3463 2557 2094 1325 785 569 453 328 213 141 115 60.5
1.70V 3307 2505 2036 1306 778 564 449 325 211 140 114 60.0
1.75V 2954 2359 1931 1267 763 553 441 320 208 138 113 59.5
1.80V 2675 2222 1815 1218 746 542 432 313 203 135 111 58.9
1.85V 2451 1958 1610 1165 725 528 422 306 198 132 109 56.6
0
Contact: Sir SHU
Phone: 13775032303
Tel: 4001177032
Email: 13775032303@139.com
Add: Room 3208, Floor 2, Rongyu Building, No. 780 Wanhangdu Road, Jing'an District, Shanghai