Game 3
Voltage value 6 V
Ampere 7.2 Ah @ 20hr rate to 1.75V per cell @ 25 ° C (77 ° F)
Weight: 1.22 kg. (2.68 lbs.)
Maximum discharge current 100A/130A (sec.)
Internal resistance Approx. 12.3 m Ω
Temperature working range Discharge: -15 ℃~50 ℃ (5 ° F~122 ° F)
Charge: -15 ℃~40 ℃ (5 ° F~104 ° F)
Storage: -15 ℃~40 ℃ (5 ° F~104 ° F)
General operating temperature range: 25 ° C ± 3 ° C (77 ° F ± 5 ° F)
Float charging uses a charging voltage of 6.75 to 6.9 VDC/unit Average at 25 ℃ (77 ° F)
Suggested maximum charging current of 2.16A
Average charging voltage of 7.2 to 7.5 VDC/unit at 25 ℃ (77 ° F)
It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temperature
Terminal F1/F2 Faston Tab187/250
ABS (UL94-HB)&Flammability resistance of (UL94-V0) can be available upon request “
Specification sheet
"GP series
GP 672"
"Valve Regulated Lead Acid Battery
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%."
General Design for Standby Power Applications
"【Design Life】
Up to 5 Years in Standby Service at 25℃
Eurobat (20℃) : 3-5 YEARS STANDARD COMMERCIAL
【 Operating Temperature Range】
Nominal Operating Temperature : 25℃(77℉) Discharge : -15℃ ~ 50℃ (5℉~122℉) Charge: -15℃ ~ 40℃ (5℉~104℉)
Storage: -15℃ ~ 40℃ (5℉~104℉)" "【 Float Charging Voltage】
6.75 ~ 6.90 VDC/Unit at 25℃ (77℉)
【Equalization Charging Voltage 】
7.2 ~ 7.5 VDC/Unit at 25℃ (77℉)
【 Self Discharge】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉)."
Specification Design according with IEC 61056-1/2:2012
"Nominal Voltage 6V (3 cells per unit)
Nominal Capacity 7.2 Ah @20hr-rate to 1.75V per cell @25℃ (77℉)
Weight Approx. 1.22 Kg (2.68 lbs) Maximum Discharge Current 100/130A (5sec)
Internal Resistance Approx. 12.3mΩ
Short Circuit Current 259A
Maximum Charge Current 2.16A
Terminal types F1/F2 terminal -Faston Tab 187/250
Terminal tightening torque --
Container Material ABS (UL 94-HB) & Flame Retardant (94-V0) available upon request
Length (L) 151.0±2.0 mm 5.94±0.08 inch
Width (W) 34.0±1.0 mm 1.34±0.04 inch
Dimensions
Container Height (h) 94.5±1.0 mm 3.72±0.04 inch
Overall Height (H) 100.7±1.5 mm 3.96±0.06 inch"
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time 5 MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 35.6 22.0 16.5 9.6 5.51 3.92 3.08 2.13 1.34 0.92 0.77 0.45
1.67V 33.1 21.0 15.9 9.4 5.41 3.85 3.02 2.08 1.31 0.90 0.76 0.44
1.70V 31.9 20.5 15.6 9.2 5.37 3.82 3.00 2.06 1.30 0.89 0.75 0.43
1.75V 29.6 19.6 15.1 9.0 5.30 3.77 2.96 2.02 1.27 0.88 0.74 0.42
1.80V 27.2 18.6 14.4 8.8 5.23 3.71 2.91 1.98 1.25 0.87 0.73 0.41
1.85V 24.5 17.4 13.7 8.4 5.14 3.66 2.87 1.95 1.22 0.86 0.71 0.40
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 180 123 91.4 53.9 32.2 23.5 18.8 13.3 8.62 5.87 4.90 2.68
1.67V 170 118 88.7 52.9 31.8 23.2 18.5 13.2 8.50 5.80 4.84 2.63
1.70V 165 115 87.2 52.4 31.6 23.1 18.4 13.1 8.45 5.76 4.77 2.61
1.75V 157 111 85.0 51.6 31.2 22.8 18.2 13.0 8.36 5.70 4.73 2.57
1.80V 147 106 82.3 50.6 30.9 22.5 18.0 12.8 8.27 5.65 4.70 2.53
1.85V 138 101 79.2 49.5 30.4 22.1 17.7 12.6 8.16 5.60 4.64 2.49