Specification sheet
Number of rounds 6
Voltage value 12 V
Ampere rating 65 Ah @ 20hr rate to 1.75V per cell @ 25 ° C (77 ° F)
Weight: 20.0kg (44.08 lbs.)
Maximum discharge current 500A (5sec.)
Internal resistance Approx. 5.8 m Ω
Temperature working range Discharge: -15 ℃~50 ℃ (5 ° F~122 ° F)
Charge: -15 ℃~40 ℃ (5 ° F~104 ° F)
Storage: -15 ℃~40 ℃ (5 ° F~104 ° F)
General operating temperature range: 25 ° C ± 3 ° C (77 ° F ± 5 ° F)
Float charging uses a charging voltage of 13.5 to 13.8 VDC/unit Average at 25 ° C (77 ° F)
Suggested maximum charging current of 19.5A
Average charging voltage of 14.4 to 15.0 VDC/unit at 25 ° C (77 ° F)
It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temperature
Terminal B4-L terminal or Received Type to accept M6 nut&bolt
Cell material Polypropylene (UL 94-HB)&Flammability resistance
Of (UL 94-V0) can be available upon request “
Specification sheet
"GP series
GP 12650"
"Valve Regulated Lead Acid Battery
Maintenance‐Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%."
General Design for Standby Power Applications
"【Design Life】
Up to 5 Years in Standby Service at 25℃
Eurobat (20℃) : 3‐5 YEARS STANDARD COMMERCIAL
【 Operating Temperature Range】
Nominal Operating Temperature : 25℃(77℉)
Discharge : ‐15℃ ~ 50℃ (5℉~122℉) Charge: ‐15℃ ~ 40℃ (5℉~104℉) Storage: ‐15℃ ~ 40℃ (5℉~104℉)" "【 Float Charging Voltage】
13.5 ~ 13.8 VDC/Unit at 25℃ (77℉)
【Equalization Charging Voltage 】
14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
【 Self Discharge】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉)."
Specification Design according with IEC 60896‐21/22: 2004
"Nominal Voltage 12V (6 cells per unit)
Nominal Capacity 65 Ah @20hr‐rate to 1.75V per cell @25℃ (77℉)
Weight Approx. 20.00 Kg (44.08 lbs) Maximum Discharge Current 500A (5sec)
Internal Resistance Approx. 5.8mΩ
Short Circuit Current 1663A
Maximum Charge Current 19.50A
Terminal types I2 terminal to accept M6 bolt
Terminal tightening torque 51.7±10.3 Kgf∙cm / 44.9±9.0 Lbf∙in / 5.10±1.0 N∙m
Container Material PP (UL 94‐HB) & Flame Retardant (94‐V0) available upon request
Length (L) 349.4±2.5 mm 13.76±0.10 inch
Width (W) 166.0±2.0 mm 6.54±0.08 inch
Dimensions
Container Height (h) 174.9±2.0 mm 6.89±0.08 inch
Overall Height (H) 174.9±2.0 mm 6.89±0.08 inch"
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time 5 MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 271 173 132 79.9 47.2 34.2 27.3 19.4 12.4 8.08 6.58 3.57
1.67V 242 162 124 78.3 46.9 34.1 27.2 19.3 12.3 7.97 6.47 3.42
1.70V 229 157 121 77.3 46.7 34.0 27.1 19.2 12.2 7.93 6.43 3.36
1.75V 208 147 117 75.4 46.4 33.8 27.0 19.1 12.1 7.86 6.32 3.25
1.80V 186 137 111 73.4 45.9 33.6 26.9 19.0 12.0 7.76 6.21 3.14
1.85V 164 127 105 71.3 45.4 33.3 26.8 18.9 11.9 7.66 6.10 3.03
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 3250 2080 1580 959 566 411 327 232 148 97.0 79.0 40.9
1.67V 2900 1940 1503 935 562 409 326 231 147 96.0 77.7 39.2
1.70V 2750 1871 1460 924 560 407 325 230 146 95.5 77.1 38.4
1.75V 2490 1760 1400 903 555 405 324 229 145 94.3 75.8 37.1
1.80V 2230 1640 1330 881 550 403 323 228 144 93.1 74.5 35.7
1.85V 1970 1520 1260 856 545 400 322 227 143 91.9 73.2 34.4
0