Game 3
Voltage value 6 V
Ampere 12 Ah @ 20hr rate to 1.75V per cell @ 25 ° C (77 ° F)
Weight: 1.85kg (4.08 lbs.)
Maximum discharge current 150A/180A (5sec.)
Internal resistance Approx. 8.9m Ω
Temperature working range Discharge: -15 ℃~50 ℃ (5 ° F~122 ° F)
Charge: -15 ℃~40 ℃ (5 ° F~104 ° F)
Storage: -15 ℃~40 ℃ (5 ° F~104 ° F)
General operating temperature range: 25 ° C ± 3 ° C (77 ° F ± 5 ° F)
Float charging uses a charging voltage of 6.75 to 6.9 VDC/unit Average at 25 ℃ (77 ° F)
Suggested maximum charging current of 3.6A
Average charging voltage of 7.2 to 7.5 VDC/unit at 25 ℃ (77 ° F)
It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temperature
Terminal F1/F2 Faston Tab187/250
ABS (UL94-HB)&Flammability resistance of (UL94-V0) can be available upon request “
Specification sheet
"GP series
GP 6120"
"Valve Regulated Lead Acid Battery
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%."
General Design for Standby Power Applications
"【Design Life】
Up to 5 Years in Standby Service at 25℃
Eurobat (20℃) : 3-5 YEARS STANDARD COMMERCIAL
【 Operating Temperature Range】
Nominal Operating Temperature : 25℃(77℉) Discharge : -15℃ ~ 50℃ (5℉~122℉) Charge: -15℃ ~ 40℃ (5℉~104℉)
Storage: -15℃ ~ 40℃ (5℉~104℉)" "【 Float Charging Voltage】
6.75 ~ 6.90 VDC/Unit at 25℃ (77℉)
【Equalization Charging Voltage 】
7.2 ~ 7.5 VDC/Unit at 25℃ (77℉)
【 Self Discharge】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉)."
Specification Design according with IEC 61056-1/2:2012
"Nominal Voltage 6V (3 cells per unit)
Nominal Capacity 12 Ah @20hr-rate to 1.75V per cell @25℃ (77℉)
Weight Approx. 1.85 Kg (4.08 lbs) Maximum Discharge Current 150/180A (5sec)
Internal Resistance Approx. 8.9mΩ
Short Circuit Current 427A
Maximum Charge Current 3.60A
Terminal types F1/F2 terminal -Faston Tab 187/250
Terminal tightening torque --
Container Material ABS (UL 94-HB) & Flame Retardant (94-V0) available upon request
Length (L) 151.0±2.0 mm 5.94±0.08 inch
Width (W) 50.0±1.0 mm 1.97±0.04 inch
Dimensions
Container Height (h) 94.3±1.0 mm 3.71±0.04 inch
Overall Height (H) 100.5±1.5 mm 3.96±0.06 inch"
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time 5 MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 51.2 33.2 23.9 13.9 8.14 5.90 4.69 3.37 2.24 1.45 1.19 0.640
1.67V 48.2 32.0 23.6 13.7 8.12 5.84 4.62 3.35 2.21 1.44 1.18 0.623
1.70V 46.3 31.6 23.3 13.6 8.08 5.82 4.61 3.32 2.18 1.43 1.17 0.610
1.75V 43.3 30.0 22.6 13.4 8.03 5.77 4.57 3.26 2.13 1.40 1.15 0.600
1.80V 38.8 28.0 21.5 13.0 7.81 5.64 4.48 3.17 2.06 1.37 1.14 0.584
1.85V 34.2 25.3 19.8 12.3 7.51 5.41 4.29 3.03 1.97 1.32 1.09 0.568
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 269 173 134 79.8 48.9 35.3 28.0 19.8 12.7 8.36 6.91 3.85
1.67V 257 171 132 79.6 48.8 35.1 27.8 19.7 12.6 8.30 6.85 3.81
1.70V 250 168 131 78.8 48.5 35.0 27.7 19.5 12.5 8.25 6.80 3.80
1.75V 231 163 128 78.1 48.1 34.6 27.5 19.3 12.2 8.12 6.69 3.77
1.80V 209 153 121 76.3 47.4 34.0 26.8 18.9 12.0 7.91 6.52 3.71
1.85V 185 140 111 72.2 45.8 33.1 26.3 18.1 11.7 7.73 6.36 3.61
0
Contact: Sir SHU
Phone: 13775032303
Tel: 4001177032
Email: 13775032303@139.com
Add: Room 3208, Floor 2, Rongyu Building, No. 780 Wanhangdu Road, Jing'an District, Shanghai