Specification
Cells Per Unit: 6
Voltage Per Unit: 12 V
Capacity: 34W @ 15 Minute-Rate to 1.67V Per Cell @ 25°C (77°F)
Weight: Approx. 2.7 kg (5.95 lbs)
Maximum Discharge Current: 130A (5 Sec)
Internal Resistance: Approx. 17 mΩ
Operating Temperature Range:
- Discharge: -15°C~50°C (5°F~122°F)
- Charge: -15°C~40°C (5°F~104°F)
- Storage: -15°C~40°C (5°F~104°F)
Nominal Operating Temperature Range: 25°C ±3°C (77°F ±5°F)
Float Charging Voltage: 13.5 to 13.8 VDC/Unit Average at 25°C (77°F)
Recommended Maximum Charging Current Limit: 3.4A
Equalization and Cycle Service: 14.4 to 15.0 VDC/Unit Average at 25°C (77°F)
Self Discharge: It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal: F2-Faston Tab 250
Container Material: ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.
HRL series
HRL 1234W
Valve Regulated Lead Acid Battery
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%.
GeneralDesign for Standby Power Applications
【Design Life】【Float Charging Voltage】
Up to 8 Years in Standby Service at 25℃13.5 ~ 13.8 VDC/Unit at 25℃ (77℉)
Eurobat (20℃): 10/12 YEARS LONG LIFE【Equalization Charging Voltage】
【Operating Temperature Range】14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
Nominal Operating Temperature: 25℃ (77℉)【Self Discharge】
Discharge: -15℃ ~ 50℃ (5℉~122℉)Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Charge: -15℃ ~ 40℃ (5℉~104℉)Fully recharging is required before usage, and charged sooner if stored
Storage: -15℃ ~ 40℃ (5℉~104℉)at higher temperature than 25℃ (77℉).
Design according with IEC 61056-1/2:2012
Length (L)150.9±2.0 mm5.94±0.08 inch
Width (W)64.8±1.0 mm2.55±0.04 inch
Dimensions
Container Height (h)94.3±1.0 mm3.71±0.04 inch
Overall Height (H)98.6±1.0 mm3.88±0.04 inch
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time2MIN4MIN5MIN6MIN8MIN10MIN15MIN20MIN30MIN45MIN60MIN90MIN
1.60V77.150.243.137.930.725.918.814.810.77.595.974.26
1.67V69.648.041.736.930.225.618.614.710.67.565.954.25
1.70V66.046.640.836.229.725.418.514.610.57.555.944.24
1.75V60.043.638.534.628.724.618.214.410.47.485.904.22
1.80V53.239.835.532.327.023.417.514.010.27.325.794.16
1.85V45.835.331.929.024.821.416.413.29.696.995.554.00
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time2MIN4MIN5MIN6MIN8MIN10MIN15MIN20MIN30MIN45MIN60MIN90MIN
1.60V75453046441233929021517112589.470.951.1
1.67V69951445240433428721317012489.270.751.0
1.70V68950344339833028421216912389.070.650.9
1.75V63947742438332127820916712288.370.250.7
1.80V58244139735930626620316312086.869.150.1
1.85V51540035932928324719115511583.466.648.5