Sales hotline:13775032303
Specification:
- Cells Per Unit: 6
- Voltage Per Unit: 12 V
- Capacity: 100 Ah @ 10hr-rate to 1.80V per cell @ 25°C (77°F)
- Weight: Approx. 38.3 Kg (84.41 lbs)
- Maximum Discharge current: 800 A (5sec)
- Internal Resistance: Approx. 3.70 mΩ
- Operating Temperature Range:
- Discharge: -15℃~50℃ (5°F~122°F)
- Charge: -15℃~40℃ (5°F~104°F)
- Storage: -15℃~40℃ (5°F~104°F)
- Nominal Operating Temperature Range: 25℃±3℃ (77°F±5°F)
- Float charging voltage: 13.5 ~ 13.8 VDC/Unit Average at 25℃ (77℉)
- Recommended Maximum Charging current limit: 30 A
- Equalization and Cycle Service: 14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
- Self Discharge: Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉)
- Terminal: I2 thread lead alloy terminal to accept M6 bolt
- Container Material: Flame Retardant ABS (UL 94-V0)
TPL series
TPL121000FR
Valve Regulated Lead Acid Battery
Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%.
General Design for Standby Power Applications
【Design Life】
Up to 12 Years in Standby Service at 25℃
Eurobat (20℃): >12 YEARS VERY LONG LIFE
【Operating Temperature Range】
Nominal Operating Temperature: 25℃ (77℉)
Discharge: -15℃ ~ 50℃ (5℉~122℉) Charge: -15℃ ~ 40℃ (5℉~104℉) Storage: -15℃ ~ 40℃ (5℉~104℉)
【Float Charging Voltage】
13.5 ~ 13.8 VDC/Unit at 25℃ (77℉)
【Equalization Charging Voltage】
14.4 ~ 15.0 VDC/Unit at 25℃ (77℉)
【Self Discharge】
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉); Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉).
Specification Design according with IEC 60896-21/22:2004
Nominal Voltage 12V (6 cells per unit)
Nominal Capacity 100AH @10HR-rate to 1.80V per cell @25℃ (77℉)
Weight Approx. 38.30 Kg (84.41 lbs)
Maximum Discharge Current 800A (5sec)
Internal Resistance Approx. 3.70 mΩ
Short Circuit Current 2216A
Maximum Charge Current 30A
Terminal types I2 thread lead alloy terminal to accept M6 bolt
Terminal tightening torque 51.7±10.3 Kgf∙cm / 44.9±9.0 Lbf∙in / 5.1±1.0 N∙m
Container Material Flame Retardant ABS (UL 94-V0)
Length (L) 511.6±2.5 mm 20.16±0.10 inch
Dimensions Width (W) 110.0±1.5 mm 4.44±0.06 inch Overall Height (H) 255.5±2.5 mm 10.11±0.10 inch
Constant Current Discharge Characteristics Unit: A (25℃, 77℉)
F.V/Time 15MIN 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 6HR 8HR 10HR 20HR
1.67V 186 118 69.1 50.2 40.1 29.6 23.8 19.8 16.9 13.0 10.6 5.56
1.70V 175 114 67.4 49.4 39.4 29.3 23.5 19.5 16.6 12.8 10.5 5.50
1.75V 157 106 64.0 47.3 38.0 28.4 22.8 18.8 16.0 12.5 10.3 5.38
1.80V 139 98.0 60.3 44.7 36.3 27.0 21.8 18.1 15.6 12.1 10.0 5.25
1.83V 129 92.5 58.0 43.5 35.1 26.1 21.1 17.6 15.2 11.7 9.63 5.13
1.85V 122 88.2 56.0 42.5 34.3 25.4 20.7 17.2 14.8 11.5 9.50 5.00
Constant Power Discharge Characteristics Unit: W (25℃, 77℉)
F.V/Time 15MIN 30MIN 60MIN 90MIN 2HR 3HR 4HR 5HR 6HR 8HR 10HR 20HR
1.67V 1969 1272 757 554 446 331 268 223 191 147 120 63.1
1.70V 1878 1233 746 549 439 329 267 222 189 145 119 62.9
1.75V 1716 1161 723 534 428 322 261 216 185 144 118 62.3
1.80V 1549 1075 691 511 414 313 254 212 183 141 116 61.6
1.83V 1450 1025 669 502 405 305 246 207 179 138 114 60.6
1.85V 1382 994 655 496 399 299 241 203 175 136 113 59.5
0
Contact: Sir SHU
Phone: 13775032303
Tel: 4001177032
Email: 13775032303@139.com
Add: Room 3208, Floor 2, Rongyu Building, No. 780 Wanhangdu Road, Jing'an District, Shanghai